{"product_id":"generators","title":"Generators","description":"\u003cp\u003e\u003cstrong\u003eAdvanced Generator Repair, Overhauling \u0026amp; Condition Monitoring Solutions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAt GTA ENGINEERING LIMITED, we provide specialized services for \u003cstrong\u003eturbo generators up to 220MW, 11kV\u003c\/strong\u003e, driven by thermal, hydro, and gas turbines. We support power plants and industrial facilities with reliable, high-quality engineering solutions.\u003c\/p\u003e\n\u003cp\u003eOur expertise covers \u003cstrong\u003ecomplete lifecycle support\u003c\/strong\u003e, from fault diagnosis to full-scale rehabilitation and performance optimization.\u003c\/p\u003e\n\u003cp\u003eWe restore generator components to optimal condition using advanced engineering techniques, including:\u003c\/p\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.5;\"\u003e\n\u003cli\u003eStator and rotor rewinding.\u003c\/li\u003e\n\u003cli\u003eInsulation repair and upgrading.\u003c\/li\u003e\n\u003cli\u003eCore damage repair and re-stacking.\u003c\/li\u003e\n\u003cli\u003eShaft and journal refurbishments.\u003c\/li\u003e\n\u003cli\u003eSlip ring and brush gear repair.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWe offer comprehensive overhaul services to extend equipment lifespan, such as:\u003c\/p\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.5;\"\u003e\n\u003cli\u003eComplete dismantling and inspection.\u003c\/li\u003e\n\u003cli\u003eReplacement of worn or damaged parts.\u003c\/li\u003e\n\u003cli\u003eBearing inspection and replacement.\u003c\/li\u003e\n\u003cli\u003eCooling system overhauls (air, hydrogen, and water-cooled systems).\u003c\/li\u003e\n\u003cli\u003eAlignment and reassembly.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWe provide real-time monitoring and predictive maintenance solutions, including:\u003c\/p\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.5;\"\u003e\n\u003cli\u003eOnline and offline testing.\u003c\/li\u003e\n\u003cli\u003eInsulation resistance and polarization index testing.\u003c\/li\u003e\n\u003cli\u003eVibration and temperature monitoring.\u003c\/li\u003e\n\u003cli\u003eWinding resistance, high voltage testing (Hi-Pot), and Tan Delta tests.\u003c\/li\u003e\n\u003cli\u003eRoot Cause Failure Analysis (RCFA).\u003c\/li\u003e\n\u003cli\u003eFinal commissioning and operational support.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWe are dedicated to delivering \u003cstrong\u003ereliable, efficient, and cost-effective generator solutions\u003c\/strong\u003e that enhance performance, extend service life, and ensure uninterrupted power generation.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp style=\"background: #FCFCFC; font-size: 16.0pt; color: black;\"\u003eTechnical Details for Generators\u003c\/p\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.5;\"\u003e\n\u003cli\u003e165MVA, 15kV 3 phase Turbo Generator Make: Alstom\/Siemens\/GE\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"overflow-x: auto; margin-bottom: 20px;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; background: #FCFCFC;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"border: 1px solid #ccc; padding: 10px; text-align: center; color: #444;\"\u003eSr. No\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #ccc; padding: 10px; text-align: center; color: #444;\"\u003eRating (MVA\/KW)\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #ccc; padding: 10px; text-align: center; color: #444;\"\u003eVoltage (kV)\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #ccc; padding: 10px; text-align: center; color: #444;\"\u003eArmature Current (Amp AC)\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #ccc; padding: 10px; text-align: center; color: #444;\"\u003eField Current (Amp AC)\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #ccc; padding: 10px; text-align: center; color: #444;\"\u003eField Voltage (V)\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #ccc; padding: 10px; text-align: center; color: #444;\"\u003eRotation (RPM)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px; text-align: center; color: #444;\"\u003e1\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px; text-align: center; color: #444;\"\u003e165\/132\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px; text-align: center; color: #444;\"\u003e15 (±5%)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px; text-align: center; color: #444;\"\u003e6351\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px; text-align: center; color: #444;\"\u003e2327\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px; text-align: center; color: #444;\"\u003e230\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px; text-align: center; color: #444;\"\u003e3000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.5;\"\u003e\n\u003cli\u003e173.6MVA, 15.75kV 3 phase Turbo Generator, Make: Alstom\/Siemens\/GE\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"overflow-x: auto; margin-bottom: 20px;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; background: #FCFCFC;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"border: 1px solid #ccc; padding: 10px; text-align: center; color: #444;\"\u003eSr. No\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #ccc; padding: 10px; text-align: center; color: #444;\"\u003eRating (MVA\/KW)\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #ccc; padding: 10px; text-align: center; color: #444;\"\u003eVoltage (kV)\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #ccc; padding: 10px; text-align: center; color: #444;\"\u003eArmature Current (Amp AC)\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #ccc; padding: 10px; text-align: center; color: #444;\"\u003eField Current (Amp AC)\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #ccc; padding: 10px; text-align: center; color: #444;\"\u003eField Voltage (V)\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #ccc; padding: 10px; text-align: center; color: #444;\"\u003eRotation (RPM)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px; text-align: center; color: #444;\"\u003e1\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px; text-align: center; color: #444;\"\u003e173\/138.29\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px; text-align: center; color: #444;\"\u003e15.75 (±5%)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px; text-align: center; color: #444;\"\u003e6048\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px; text-align: center; color: #444;\"\u003e1100\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px; text-align: center; color: #444;\"\u003e229\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px; text-align: center; color: #444;\"\u003e3000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"GTA Engineering","offers":[{"title":"Default Title","offer_id":52779240882485,"sku":null,"price":0.0,"currency_code":"INR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/3779\/6917\/files\/IMG-20250920-WA0010_b945dbf7-4765-4cfe-977f-408556fbf015.jpg?v=1777628429","url":"https:\/\/gta.uk.com\/products\/generators","provider":"GTA Engineering","version":"1.0","type":"link"}