{"product_id":"turbines","title":"Turbines","description":"\u003cp\u003e\u003cstrong\u003eHYDRO, STEAM AND GAS TURBINES:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePowering Reliability. Restoring Performance.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eGTA ENGINEERING LIMITED is one of Africa’s leading engineering service providers specializing in the repair, reconditioning, overhauling, troubleshooting, erection, and commissioning of hydro, steam, and gas turbines.\u003c\/p\u003e\n\u003cp\u003eWith decades of hands-on expertise and a commitment to quality, we deliver world-class solutions that enhance performance, extend equipment life, and minimize downtime for power generation and industrial clients across Africa.\u003c\/p\u003e\n\u003cp\u003eGTA ENGINEERING LIMITED is a premier service facility dedicated to the maintenance and rehabilitation of critical rotating equipment. With a highly skilled team and advanced workshop capabilities, we provide end-to-end solutions.\u003c\/p\u003e\n\u003cp\u003eWe restore turbines to optimal operating condition through:\u003cbr\u003eRepair and reconditioning of turbine rotors, diaphragms, and guide blade carriers.\u003cbr\u003eComprehensive re-blading services.\u003c\/p\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.5;\"\u003e\n\u003cli\u003eRemoving and replacing gland fins and inter-stage fins of rotors.\u003c\/li\u003e\n\u003cli\u003eRemoval, replacing, and turning of gland fins for all steam glands.\u003c\/li\u003e\n\u003cli\u003eBabbitting and machining of journal bearings and thrust pads.\u003c\/li\u003e\n\u003cli\u003eDynamic balancing.\u003c\/li\u003e\n\u003cli\u003eNDT (Non-Destructive Testing) and RLA (Remaining Life Assessment) studies.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eComprehensive overhauls to ensure peak performance through major and minor overhauls, preventive and predictive maintenance, inspection and condition assessment, and performance optimization.\u003c\/p\u003e\n\u003cp\u003eRapid fault detection and resolution, including vibration analysis, thermal and electrical diagnostics, root cause failure analysis (RCFA), and emergency breakdown support.\u003c\/p\u003e\n\u003cp\u003eWe provide services through extensive experience in turbine and generator servicing, advanced workshop facilities with modern equipment, highly skilled engineers and technicians, fast turnaround times to minimize downtime, quality assurance in line with international standards, and customer-focused solutions tailored to your needs.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp style=\"background: #FCFCFC; font-size: 16.0pt; color: black;\"\u003eTechnical Details for Generators\/Turbines\u003c\/p\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.5;\"\u003e\n\u003cli\u003e165MVA, 15kV 3 phase Turbo Generator Make: Alstom\/Siemens\/GE\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"overflow-x: auto; margin-bottom: 20px;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; background: #FCFCFC;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"border: 1px solid #ccc; padding: 10px; text-align: center; color: #444;\"\u003eSr. No\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #ccc; padding: 10px; text-align: center; color: #444;\"\u003eRating (MVA\/KW)\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #ccc; padding: 10px; text-align: center; color: #444;\"\u003eVoltage (kV)\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #ccc; padding: 10px; text-align: center; color: #444;\"\u003eArmature Current (Amp AC)\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #ccc; padding: 10px; text-align: center; color: #444;\"\u003eField Current (Amp AC)\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #ccc; padding: 10px; text-align: center; color: #444;\"\u003eField Voltage (V)\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #ccc; padding: 10px; text-align: center; color: #444;\"\u003eRotation (RPM)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px; text-align: center; color: #444;\"\u003e1\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px; text-align: center; color: #444;\"\u003e165\/132\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px; text-align: center; color: #444;\"\u003e15 (±5%)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px; text-align: center; color: #444;\"\u003e6351\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px; text-align: center; color: #444;\"\u003e2327\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px; text-align: center; color: #444;\"\u003e230\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px; text-align: center; color: #444;\"\u003e3000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.5;\"\u003e\n\u003cli\u003e173.6MVA, 15.75kV 3 phase Turbo Generator, Make: Alstom\/Siemens\/GE\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"overflow-x: auto; margin-bottom: 20px;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; background: #FCFCFC;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"border: 1px solid #ccc; padding: 10px; text-align: center; color: #444;\"\u003eSr. No\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #ccc; padding: 10px; text-align: center; color: #444;\"\u003eRating (MVA\/KW)\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #ccc; padding: 10px; text-align: center; color: #444;\"\u003eVoltage (kV)\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #ccc; padding: 10px; text-align: center; color: #444;\"\u003eArmature Current (Amp AC)\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #ccc; padding: 10px; text-align: center; color: #444;\"\u003eField Current (Amp AC)\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #ccc; padding: 10px; text-align: center; color: #444;\"\u003eField Voltage (V)\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #ccc; padding: 10px; text-align: center; color: #444;\"\u003eRotation (RPM)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px; text-align: center; color: #444;\"\u003e1\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px; text-align: center; color: #444;\"\u003e173\/138.29\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px; text-align: center; color: #444;\"\u003e15.75 (±5%)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px; text-align: center; color: #444;\"\u003e6048\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px; text-align: center; color: #444;\"\u003e1100\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px; text-align: center; color: #444;\"\u003e229\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px; text-align: center; color: #444;\"\u003e3000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"GTA Engineering","offers":[{"title":"Default Title","offer_id":52779240063285,"sku":null,"price":0.0,"currency_code":"INR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/3779\/6917\/files\/WhatsAppImage2026-05-01at17.16.34.jpg?v=1777883540","url":"https:\/\/gta.uk.com\/products\/turbines","provider":"GTA Engineering","version":"1.0","type":"link"}